15
15EN
MANUAL ELDES ESIM264 V3.1
Type 3 Example of motion detector wiring
Z1
COM
COM
AUX+
AUX-
+Vin
GND
NC
TAMP
5,6 kΩ 3,3 kΩ
5
6-Zone mode: Tamper
and 5,6K end-of-line
resistor and 3,3K
end-of-line resistor
with normally closed
contact.
Type 4 Example of magnetic door contact (Z1) and glass break sensor (Z7) wiring
AUX+
+Vin
AUX-
GND
COM
COM
NC
NC
COM
Z1
5,6 kΩ
3,3 kΩ
Magnet
6
ATZ mode: 5,6K
end-of-line resistor
and normally closed
contact with 3,3K
end-of-line resistor
and normally closed
contact
Type 5 Example of motion detector (Z1) and magnetic door contact (Z7) wiring
Z1
COM
COM
COM
AUX+
AUX-
+Vin
GND
NC
NC
TAMP
5,6 kΩ5,6 kΩ 3,3 kΩ
Magnet
ATZ mode: Tamper,
5,6K end-of-line
resistor, 5,6K
end-of-line resistor
with normally closed
contact and 3,3K
end-of-line resistor
with normally closed
contact.
7
See also 14.3. 6-Zone Mode and 14.4. ATZ (Advanced Technology Zone) Mode.