4.3.3 Zones commands
ATZ Mode
WhenATZmode(zoneduplication)isenabled,thezonenumberisincreasedto12.Byde-
fault,ATZmodeisdisabled.
Enter code 28 and function:
Disabled–[280#]
Enabled-[281#]
EKB3
Arm-Disarm
By Zone
Zone Mode No ATZ
ChoosethezonewhichwillworkinArm-Disarmmode.Withthiszonesecuritysystemcanbe
activated/deactivatedwitha“low”levelimpulsewhichisnotshorterthan3seconds.Thismode
canbesetonlyforonezone.Noresistanceisconnectedwhenusing6zoneconnectiontype
andtheinputmustbeNO(normallyopen).IfATZmodeisenabledtheimpulseistransmitted
throughresistance.IfZ2-Z6zonesareused,theimpulseshouldbetransmittedthrough5.6k
resistance,ifZ7-Z12zones-theimpulseshouldbetransmittedthrough3.3kresistance.
In the environment of ESIM264 Conguration Tool the user must specify the mode
of connected Zones:
• Type1–Normallyopencontactwith5,6KΩendoflineresistor.
• Type2–Normallyclosedcontactwith5,6KΩendoflineresistor.
• Type3–Tamperand5,6KΩend oflineresistorand3,3KΩendof line resistorwith
normallyclosedcontact.
Enter code 34 and zone number:
Zone1–[3401#]
Zone2–[3402#]
Zone3–[3403#]
…
Zone12-[3412#]
Disabled–[3400#]
EKB3
Enter code 38 and Zone mode:
Type1–[381#]
Type2–[382#]
Type3–[383#]
EKB3