4.3.4 Monitoring station commands
CID Enable
CID Messages
Whenthisfunctionisenabled,thesystemgeneratesCONTACTIDmessagesanddelivers
themtomonitoringstations.Whenthisfunctionisdisabled,thesystemoperatesinnormal
mode,i.e.,deliversmessagesonlytoregisteredusers(othercongurationsinMSSettings
sectionbecomesinactive).
CongurewhichContactIDmessageswillbedeliveredtomonitoringstation.Bydefault,
allthesemessagesareactivated.
Alarm/Restore Event –themessagesaboutsystemalarmandrestoreevents.
External Power Loss/Restore Event –themessagesaboutexternalpowersupplylossand
restoreevents.
Akum Status Event–themessagesaboutbackupbatteryatstatus.
Armed Event -themessagesaboutsecuritysystemarmingevents.
Disarmed Event -themessagesaboutsecuritysystemdisarmingevents.
Test Event -themessageswithtestinformationaboutthestatusofthedevice.
Enter code 23 and function:
Disabled–[230#]
Enabled-[231#]
Enter code 24, event number and function:
Alarm/RestoreEvent-[2401x#]
ExternalPowerLoss/RestoreEvent-[2402x#]
AkumStatusEvent-[2403x#]
ArmedEvent-[2404x#]
DisarmedEvent-[2405x#]
TestEvent-[2406x#]
where x – 0: disabled, 1: enabled.