128
128 EN
MANUAL ELDES ESIM264 V3.1
D1
LED
D2
C2
COM
DC+
Z1
C1
Z2
58
+12V
EW1
Power supply
DC+ C1 C2 Z1 Z2 COM
59
32.2.1.2. Connector & LED Functionality
COM Common terminal for power supply, zones
Z2, Z1 Security zone terminals
C2, C1 PGM output terminals
DC+ Positive power supply terminal
D1, D2 Pins for restoring default parameters
LED EW1 status
32.2.2. Installation
1. Disconnect ESIM264 alarm system main power supply and backup battery.
2. Wire up EW1 as indicated in Fig. No. 59.
3. Bind the device to the alarm system by sending a corresponding command via SMS text message or using ELDES Conguration Tool
software. Please, refer to the software‘s HELP section or refer to 19.1. Binding, Removing and Replacing Wireless Devices for
more details.
4. T he system automatically informs about successful/unsuccessful binding process. If attempt to bind is unsuccessful, try to move EW1
closer to ESIM264 alarm system device and bind it again.
5. EW1 module is ready for use.
NOTE: If you are unable to bind the wireless device please , restore the parameters of the wireless device to default and try again. See
33.2.4 Restoring Default Parameters for more details.
ATTENTION: The minimum wireless connection range between the wireless device and wireless antenna of ESIM264 system can be
0,5 meters.
32.2.3. EW1 Zones, PGM Outputs & Tamper
Upon successful EW1 module binding process, the system adds 2 wireless Instant zones intended for wired sensor connection and 2 wireless
PGM outputs intended for electrical appliance connection and control.
The wireless connection loss between EW1 and ESIM264 alarm system leads to system alarm regardless of system being armed or disarmed.
The system identies this event as a tamper violation and sends alarm by SMS text message and phone call to the user (-s) by default. The
SMS text message contains the violated tamper number and a star * character indicating wireless connection loss as a tamper alarm cause.
ATTENTION: The tamper will not operate if both wireless zones are disabled.
32.2.4. Restoring Default Parameters
1. Disconnect EW1 power supply.
2. Short circuit (connect) pins D1 and D2.
3. Power up EW1 and wait until LED provides several short ashes.
4. Disconnect power supply.
5. Remove short-circuit from D1 and D2 pins.
6. Power up EW1.
7. Parameters restored to default.