52
52 EN
MANUAL ELDES ESIM264 V3.1
Cong
Tool
This operation may be carried out from the PC using the ELDES Conguration Tool software.
Disable Stay attribute
for individual zone
EKB2
Menu path:
On-board zone: OK → CONFIGURATION → OK → aaaa → OK → ZONES → OK → ONBOARD
ZONES → OK → ZONE 1... 12 → OK → STAY → OK → DISABLE → OK
Wireless zone: OK → CONFIGURATION → OK → aaaa → OK → ZONES → OK → WIRELESS
ZONES → OK → WLESS ZONE 1... 16 → OK → STAY → OK → DISABLE → OK
Keypad zone: OK → CONFIGURATION → OK → aaaa → OK → ZONES → OK → KEYPAD
ZONES → OK → KEYPAD 1... 4 ZONE → OK → STAY → OK → DISABLE → OK
EPGM1 zone: OK → CONFIGURATION → OK → aaaa → OK → ZONES → OK → EPGM1
ZONES → OK → EPGM1 ZONE 1... 16 → OK → STAY → OK → DISABLE → OK
Value: aaaa – 4-digit administrator password.
EKB3
Enter parameter 56, zone number & parameter status value:
56 nn 0 #
Value: nn – zone number, range – [01... 44].
Example: 56190#
Cong
Tool
This operation may be carried out from the PC using the ELDES Conguration Tool software.
Enable Force attribute
for individual zone
EKB2
Menu path:
On-board zone: OK → CONFIGURATION → OK → aaaa → OK → ZONES → OK → ONBOARD
ZONES → OK → ZONE 1... 12 → OK → FORCE → OK → ENABLE → OK
Wireless zone: OK → CONFIGURATION → OK → aaaa → OK → ZONES → OK → WIRELESS
ZONES → OK → WLESS ZONE 1... 16 → OK → FORCE → OK → ENABLE → OK
Keypad zone: OK → CONFIGURATION → OK → aaaa → OK → ZONES → OK → KEYPAD ZONES
→ OK → KEYPAD 1... 4 ZONE → OK → FORCE → OK → ENABLE → OK
EPGM1 zone: OK → CONFIGURATION → OK → aaaa → OK → ZONES → OK → EPGM1 ZONES →
OK → EPGM1 ZONE 1... 16 → OK → FORCE → OK → ENABLE → OK
Value: aaaa – 4-digit administrator password.
EKB3
Enter parameter 82, zone number & parameter status value:
82 nn 1 #
Value: nn – zone number, range – [01... 44].
Example: 82061#
Cong
Tool
This operation may be carried out from the PC using the ELDES Conguration Tool software.
Disable Force
attribute for
individual zone
EKB2
Menu path:
On-board zone: OK → CONFIGURATION → OK → aaaa → OK → ZONES → OK → ONBOARD
ZONES → OK → ZONE 1... 12 → OK → FORCE → OK → DISABLE → OK
Wireless zone: OK → CONFIGURATION → OK → aaaa → OK → ZONES → OK → WIRELESS
ZONES → OK → WLESS ZONE 1... 16 → OK → FORCE → OK → DISABLE → OK
Keypad zone: OK → CONFIGURATION → OK → aaaa → OK → ZONES → OK → KEYPAD
ZONES → OK → KEYPAD 1... 4 ZONE → OK → FORCE → OK → DISABLE → OK
EPGM1 zone: OK → CONFIGURATION → OK → aaaa → OK → ZONES → OK → EPGM1 ZONES
OK → EPGM1 ZONE 1... 16 → OK → STAY → OK → DISABLE → OK
Value: aaaa – 4-digit administrator password.
EKB3
Enter parameter 82, zone number & parameter status value:
82 nn 0 #
Value: nn – zone number, range – [01... 44].
Example: 82110#