50 EN
MANUAL ELDES ESIM264 V3.1
Set zone connection
type for ATZ mode
EKB2
Menu path:
OK CONFIGURATION OK aaaa OK ZONES OK ZONE TYPE:ATZ MODE
OK TYPE 4... 5 OK
Value: aaaa – 4-digit administrator password.
EKB3
Enter parameter 38 & number of zone connection type:
38 1 # – Type 4
38 2 # – Type 5
Example: 381#
Cong
Tool
This operation may be carried out from the PC using the ELDES Conguration Tool software.
NOTE: The ATZ mode applies to on-board zones only when enabled.
14.5. Zone Type Denitions
Interior Follower – The zone can be violated during exit and entry delay without causing an alarm. If the zone is violated before the
entry delay has begun, it will cause an instant alarm followed by single notication delivery even if the zone has been violated multiple
times or another Interior Follower-type zone has been violated while alarm period (by default - 1 minute) is in progress. The zone is
used where violating a zone during exit/entry delay is unavoidable. Typically, this zone is used for indoor protection devices, such as
motion detectors, installed close to the exit/entry doors.
Instant – The alarm is instantly caused if this zone is violated when the system is armed or during entry delay. This zone type is usually
used for doors, windows or other zones, and shock detectors.
24-Hour – When the system is either armed or disarmed, the zone will cause instant alarm if violated. Normally, this type of zone is
used for securing the areas that require constant supervisory.
Delay – This zone type can be violated during exit and entry delay without causing an alarm. If the zone is violated when the system
is armed, it will initiate entry delay countdown intended for the user to disarm the system. If the zone is left violated after the exit
delay expires, it will cause an instant alarm. If one more zone with Stay-enabled attribute exist and the Delay-type zone is not violated
and restored during exit delay, the system will be armed in Stay mode (see 15. STAY MODE). Typically, this zone type is used for door
contacts installed at designated exit/entry doors.
Fire – If this zone type is violated when the system is either armed or disarmed, the alarm will be instantly caused and the siren/bell will
emit pulsating sound. Typically, this zone type is used for ame and smoke detectors.
Panic/Silent – This zone operates the same as 24-Hour zone type, but the system will not activate the siren/bell and keypad buzzer if
violated. Normally, this zone type used for panic alarm buttons.
Set zone type for
individual zone
EKB2
Menu path:
On-board zone: OK CONFIGURATION OK aaaa OK ZONES OK ONBOARD
ZONES OK ZONE 1... 12 OK TYPE OK INTERIOR FOLLOWER | INSTANT | 24-
HOUR | DELAY | FIRE | PANIC/SILENT OK
Wireless zone: OK CONFIGURATION OK aaaa OK ZONES OK WIRELESS
ZONES 1... 4 OK WLESS ZONE 1... 16 OK TYPE OK INTERIOR FOLLOWER |
INSTANT | 24-HOUR | DELAY | FIRE | PANIC/SILENT OK
Keypad zone: OK CONFIGURATION OK aaaa OK ZONES OK KEYPAD ZONES
OK KEYPAD 1... 4 ZONE OK TYPE OK INTERIOR FOLLOWER | INSTANT | 24-
HOUR | DELAY | FIRE | PANIC/SILENT OK
EPGM1 zone: OK CONFIGURATION OK aaaa OK ZONES OK EPGM1 ZONES
OK EPGM1 ZONE 1... 16 OK TYPE OK INTERIOR FOLLOWER | INSTANT | 24-HOUR |
DELAY | FIRE | PANIC/ SILENT OK
Value: aaaa – 4-digit administrator password.
EKB3
Enter parameter 53, zone number & zone type number:
53 nn 1 # – Interior Follower
53 nn 2 # – Instant
53 nn 3 # –24-Hour
53 nn 4 # – Delay
53 nn 5 # – Fire
53 nn 6 # – Panic/Silent
Value: nn – zone number, range – [01... 44]
Example: 53125#