21. BACKUP BATTERY, MAINS POWER SUPPLY STATUS MONITORING AND MEMORY
The system may come equipped with a backup battery maintaining power supply of the system when the mains power supply is temporally
lost. The implemented feature allows the system to perform a self-test on the backup battery and notify User 1 by SMS text message as
well as to indicate system fault by the keypad (see 29. INDICATION OF SYSTEM FAULTS) if:
• battery has failed and requires replacement – battery resistance is 2 or higher; self-tested every 24 hours.
• battery power is running low – battery voltage is 10.5V or lower; constantly self-tested.
By default, all notications regarding the backup battery status are enabled. To disable/enable a determined backup battery notication,
please refer to the following conguration methods.
Disable Battery Failed
notication
EKB2
Menu path:
OK → CONFIGURATION → OK → aaaa → OK → SMS MESSAGES → OK → BATTERY FAIL EVENT
→ OK → DISABLE → OK
Value: aaaa – 4-digit administrator password.
EKB3
Enter parameter 25, notication number & parameter status value:
25 09 0 #
Example: 25090#
Cong
Tool
This operation may be carried out from the PC using the ELDES Conguration Tool software.
Enable Battery Failed
notication
EKB2
Menu path:
OK → CONFIGURATION → OK → aaaa → OK → SMS MESSAGES → OK → BATTERY FAIL EVENT
→ OK → ENABLE → OK
Value: aaaa – 4-digit administrator password.
EKB3
Enter parameter 25, notication number & parameter status value:
25 09 1 #
Example: 25091#
Cong
Tool
This operation may be carried out from the PC using the ELDES Conguration Tool software.
Disable Low Battery
notication
EKB2
Menu path:
OK → CONFIGURATION → OK → aaaa → OK → SMS MESSAGES → OK → LOW BATTERY EVENT
→ OK → DISABLE → OK
Value: aaaa – 4-digit administrator password.
EKB3
Enter parameter 25, notication number & parameter status value:
25 06 0 #
Example: 25060#
Cong
Tool
This operation may be carried out from the PC using the ELDES Conguration Tool software.