142
142 EN
MANUAL ELDES ESIM264 V3.1
NOTE: If you are unable to bind the wireless device please , restore the parameters of the wireless device to default and try again. See
33.8.5. Restoring Default Parameters for more details.
ATTENTION: The minimum wireless connection range between the wireless device and wireless antenna of ESIM264 system can be 0,5
meters.
32.8.3. EW1B Zones, PGM Outputs & Tamper
Upon successful EW1B module binding process, the system adds 2 wireless Instant zones intended for wired sensor connection and 2 wire-
less PGM outputs intended for electrical appliance connection and control. The wireless connection loss between EW1B and ESIM264 alarm
system leads to system alarm regardless of system being armed or disarmed. The system identies this event as a tamper violation and sends
alarm by SMS text message and phone call to the user (-s) by default. The SMS text message contains the violated tamper number and a star *
character indicating wireless connection loss as a tamper alarm cause.
32.8.4. Battery Replacement
1. Open EW1B enclosure.
2. Remove all 3 old batteries from the battery slots.
3. Postition the 3 new 1,5V alkaline AA type batteries according to the appropriate battery slot positive/negative terminals as indicated.
4. Insert the batteries into the battery slots.
5. Batteries replaced.
For more details, please refer to 32.8.2. Installation.
ATTENTION: Only 1,5V Alkaline AA type batteries can be used. Install only new, high quality and unexpired batteries. Do not mix the old
batteries with the new ones.
ATTENTION: At least 1 battery must be removed if the device is not in use.
ATTENTION: In order to avoid re or explosion hazards, the system must be used only with approved battery. Special care must be
taken when connecting positive and negative battery terminals. Dispose old batteries only into special collection sites. Do not charge,
disassemble, heat or incinerate old batteries.
NOTE: The system sends an SMS message to a preset User 1 as soon as the battery level runs below 5%.
NOTE: The battery status can be monitored in real-time using ELDES Conguration Tool software.
32.8.5. Restoring Default Parameters
1. Remove any battery from EW1B.
2. Short circuit (connect) pins D1 and D2.
3. Insert the battery back to EW1B.
4. Wait untill LED provides several short ashes.
5. Remove short-circuit from D1 and D2 pins.
6. Parameters restored to default.
Przeglądanie stron 141