MANUAL ELDES ESIM264 V3.1
26. SYSTEM INFORMATION. INFO SMS
The system supports an informational SMS text message identied as the Info SMS, which can be delivered upon request. Once requested,
the system will reply with Info SMS that provides the following:
System date & time.
System status: partition armed (ON)/disarmed (OFF).
GSM signal strength.
Mains power supply status.
Temperature of the area surrounding the temperature sensor (if any).
State of zones (OK/alarm).
Name and status (ON/OFF) of PGM outputs.
Request for system
information
SMS
SMS text message content:
ssss_INFO
Value: ssss – 4-digit SMS password.
Example: 1111_INFO
Cong
Tool
This operation may be carried out from the PC using the ELDES Conguration Tool software.
26.1. Periodic Info SMS
By default, the system sends Info SMS to User 1 phone number periodically once a day at 11:00 (frequency – 1 day; time – 11). The mini-
mum period is every 1 hour (frequency – 0 days; time – 1). Typically, this feature is used to verify the power supply and online status of the
system.
To set a dierent frequency and time or disable periodic Info SMS, please refer to the following conguration methods.
Set periodic Info SMS
frequency and time
SMS
SMS text message content:
ssss_INFO:f:it
Value: ssss – 4-digit SMS password; f – frequency, range – [00... 99] days; it – time, range
– [01... 23].
Example: 1111_INFO:3.15
EKB2
Menu path:
Frequency: OK CONFIGURATION OK aaaa PRIMARY SETTINGS OK INFO SMS
SCHEDULER OK FREQUENCY (DAYS) f OK
Time: OK CONFIGURATION OK aaaa PRIMARY SETTINGS OK INFO SMS
SCHEDULER OK TIME it OK
Value: aaaa – 4-digit administrator password; f – frequency, range – [00... 125] days; it
time, range – [01... 23].
EKB3
Enter parameter 11, time & frequency:
11it f #
Value: it – time, range – [01... 23]; f – frequency, range – [00... 125] days.
Example: 110412#
Cong
Tool
This operation may be carried out from the PC using the ELDES Conguration Tool software.
Disable periodic Info
SMS
SMS
SMS text message content:
ssss_INFO:00:00
Example: 1111_INFO:00.00
EKB2
Menu path:
Frequency: OK CONFIGURATION OK aaaa PRIMARY SETTINGS OK INFO SMS
SCHEDULER OK FREQUENCY (DAYS) 0 OK
Time: OK CONFIGURATION OK aaaa PRIMARY SETTINGS OK INFO SMS
SCHEDULER OK TIME 0 OK
Value: aaaa – 4-digit administrator password.
Przeglądanie stron 83
1 2 ... 79 80 81 82 83 84 85 86 87 88 89 ... 167 168

Komentarze do niniejszej Instrukcji

Brak uwag