30
30 EN
MANUAL ELDES ESIM264 V3.1
8. USER PHONE NUMBERS
The system supports up to 5 user phone numbers identied as User 1 through 5. When the phone number is set, the user will be able to
arm/disarm the system by SMS text messages and free of charge phone calls (see 12.1. Free of Charge Phone Call and 12.2. SMS Text
Message) as well as to congure the system by SMS text messages. User phone numbers are also used to receive alarm phone calls and
SMS text messages from the system (see 17. ALARM INDICATIONS AND NOTIFICATIONS).
By default, the system ignores any incoming calls and SMS text messages from a non-preset phone number as well as it rejects the SMS text
messages containing wrong SMS password even from a preset user phone number (see 8.2. System Control from any Phone Number).
To set User 1 phone number is mandatory, while the other 4 are optional. The supported phone number format is the following:
• International (w/o plus) – The phone numbers must be entered starting with an international country code in the following for-
mat: [international code][area code][local number], example for UK: 4417091111111.
Set user phone
number
SMS
SMS text message content:
ssss_NRup:ttteeellnnuumm
Value: ssss – 4-digit SMS password; up – user phone number slot, range – [1... 5]; ttteeelln-
nuumm – up to 15 digits user phone number.
Example: 1111_NR1:4417091111111
EKB2
Menu path:
OK → CONFIGURATION → OK → aaaa → OK → PRIMARY SETTINGS → OK → CALL/SMS SETTINGS
→ OK → USERS → OK → USER 1... 5 → OK → PHONE NUMBER → OK → ttteeellnnuumm → OK
Value: aaaa – 4-digit administrator password; ttteeellnnuumm – up to 15 digits user phone
number.
EKB3
Enter parameter 17, user phone number slot & phone number:
17 up ttteeellnnuumm #
Value: up – user phone number slot, range – [01... 05]; ttteeellnnuumm – up to 15 digits user
phone number.
Example: 17014417091111111#
Cong
Tool
This operation may be carried out from the PC using the ELDES Conguration Tool software.
View user phone
number
SMS
SMS text message content:
ssss_HELPNR
Value: ssss – 4-digit SMS password.
Example: 1111_HELPNR
EKB2
Menu path:
OK → CONFIGURATION → OK → aaaa → OK → PRIMARY SETTINGS → OK → CALL/SMS
SETTINGS → OK → USERS → OK → USER 1... 5 → OK → PHONE NUMBER → PHONE NUMBER
Value: aaaa – 4-digit administrator password.
Cong
Tool
This operation may be carried out from the PC using the ELDES Conguration Tool software.