76
76 EN
MANUAL ELDES ESIM264 V3.1
Disable mains
power supply restore
notication
EKB2
Menu path:
OK → CONFIGURATION → OK → aaaa → OK → SMS MESSAGES → OK → MAIN PWR REST EV →
OK → DISABLE → OK
Value: aaaa – 4-digit administrator password.
EKB3
Enter parameter 25, notication number & parameter status value:
25 05 0 #
Example: 25050#
Cong
Tool
This operation may be carried out from the PC using the ELDES Conguration Tool software.
Enable mains power
supply restore
notication
EKB2
Menu path:
OK → CONFIGURATION → OK → aaaa → OK → SMS MESSAGES → OK → MAIN PWR REST EV →
OK → ENABLE → OK
Value: aaaa – 4-digit administrator password.
EKB3
Enter parameter 25, notication number & parameter status value:
25 05 1 #
Example: 25051#
Cong
Tool
This operation may be carried out from the PC using the ELDES Conguration Tool software.
By default, mains power supply loss and restore delay are 30 and 120 seconds respectively. To set a dierent mains power supply loss and
restore delay duration, please refer to the following conguration methods.
Set mains power
supply loss delay
EKB2
Menu path:
OK → CONFIGURATION → OK → aaaa → OK → PRIMARY SETT INGS → OK → MAIN POWER
STATUS → OK → LOSS DELAY → OK → lllll → OK
Value: aaaa – 4-digit administrator password; lllll – mains power loss delay duration, range
- [0... 65535] seconds.
EKB3
Enter parameter 70 & loss delay duration:
70 lllll #
Value: lllll – mains power loss delay duration, range - [0... 65535] seconds.
Example: 7043#
Cong
Tool
This operation may be carried out from the PC using the ELDES Conguration Tool software.
Set mains power
supply restore delay
EKB2
Menu path:
OK → CONFIGURATION → OK → aaaa → OK → PRIMARY SETT INGS → OK → MAIN POWER
STATUS → OK → RESTORE DELAY → OK → rrrrr → OK
Value: aaaa – 4-digit administrator password; rrrrr – mains power restore delay duration,
range - [0... 65535] seconds.
EKB3
Enter parameter 71 & restore delay duration:
71 rrrrr #
Value: rrrrr – mains power restore delay duration, range - [0... 65535] seconds.
Example: 71150#
Cong
Tool
This operation may be carried out from the PC using the ELDES Conguration Tool software.
The conguration settings and event log records are stored in a built-in EEPROM memory, therefore even if the system is fully shut down,
the conguration and event log remain. For more details regarding the event log, please refer to 28. EVENT LOG