64
64 EN
MANUAL ELDES ESIM264 V3.1
EKB2
Menu path:
On-board PGM output: OK → CONFIGURATION → OK → aaaa → OK → PGM OUTPUTS → OK
→ ONBOARD OUTPUTS → OK → OUTPUT 1... 12 → OK → STATUS → OK → ENABLED → OK
Value: aaaa – 4-digit administrator password.
EKB3
Enter parameter 61, PGM output number & parameter status value:
61 oo 1 #
Value: oo – PGM output number, range – [01... 76].
Example: 61031#
Cong
Tool
This operation may be carried out from the PC using the ELDES Conguration Tool software.
Turn OFF PGM output/
Set PGM output start-
up state as OFF
SMS
SMS text message content:
ssss_Coo:OFF or ssss_out-name:OFF
Value: ssss – 4-digit SMS password; oo – PGM output number, range – [1... 76]; out-name –
up to 16 characters PGM output name.
Example: 1111_C2:OFF
EKB2
Menu path:
On-board PGM output: OK → CONFIGURATION → OK → aaaa → OK → PGM OUTPUTS → OK
→ ONBOARD OUTPUTS → OK → OUTPUT 1... 12 → OK → STATUS → OK → DISABLED → OK
Value: aaaa – 4-digit administrator password.
EKB3
Enter parameter 61, PGM output number & parameter status value:
61 oo 0 #
Value: oo – PGM output number, range – [01... 76].
Example: 61020#
Cong
Tool
This operation may be carried out from the PC using the ELDES Conguration Tool software.
To instantly turn ON an individual PGM output for a determined time period and automatically turn it OFF when the time period expires,
please refer to the following conguration method.
Turn ON PGM output
for time period
SMS
SMS text message content:
ssss_Coo:ON:hr.mm.sc or ssss_out-name:ON:hr.mn.sc
Value: ssss – 4-digit SMS password; oo – PGM output number, range – [1... 76]; out-name
– up to 16 characters PGM output name; hr – hours, range – [00... 23]; mn – minutes, range
– [00... 59]; sc – seconds, range – [00... 59].
Example: 1111_C4:ON:10.15.35
To instantly turn OFF an individual PGM output for a determined time period and automatically turn it ON when the time period expires,
please refer to the following conguration method.
Turn OFF PGM output
for time period
SMS
SMS text message content:
ssss_Coo:OFF:00.00.sc or ssss_out-name:OFF:hr.mn.sc
Value: ssss – 4-digit SMS password;oo – PGM output number, range – [1... 76]; out-name
– up to 16 characters PGM output name; hr – hours, range – [00... 23]; mn – minutes, range
– [00... 59]; sc – seconds, range – [00... 59].
Example: 1111_Lights:OFF:00.00.23
When the PGM output is turned ON or OFF, the system will send a conrmation by SMS text message to the user phone number that the
SMS text message was sent from.
NOTE FOR EKB2/EKB3/CONFIG TOOL USERS: Only the startup state of the PGM output can be changed using these conguration